Determination of Effective Thermal Conductivity of Stipa ichu: Numerical Shape Factor Calibration in a Reduced-Scale Hot Box
DOI:
https://doi.org/10.18687/LACCEI2026.1.1.1705Palabras clave:
StipaIchu, Thermal Conductivity, Hot Box, CFD, Shape Factor.Resumen
Energy vulnerability in High-Andean dwellings necessitates the development of efficient, indigenous thermal insulation solutions. This study characterizes the thermal conductivity of Stipa Ichu fiber using a geometrically corrected, reduced-scale Hot Box method. To mitigate the metrological uncertainty inherent to low-cost devices, a hybrid experimental-numerical (CFD) methodology was implemented. Analysis using the SST k- turbulence model revealed that scale reduction induces significant multidimensional heat fluxes at the edges; consequently, a shape efficiency factor of η = 0.47 was established. Upon applying this systematic correction, an effective thermal conductivity of was determined for a compaction density of 150 kg/m3. These results validate Stipa Ichu fiber as a competitive alternative to conventional insulators, providing a viable technical solution for mitigating extreme cold conditionsDescargas
Publicado
2026-07-27
Número
Sección
Articles
Derechos de autor
Derechos de autor 2026 LACCEI
Licencia
Esta obra está bajo una Licencia Creative Commons Atribución-NoComercial-CompartirIgual 4.0 Internacional.
LACCEI conserva el copyright de todos los artículos publicados bajo los términos de su acuerdo de transferencia de copyright. Como titular del copyright, LACCEI distribuye los artículos al público bajo la Licencia Internacional Creative Commons Atribución-NoComercial-CompartirIgual 4.0 (CC BY-NC-SA 4.0).
Cómo citar
Quispe Esperilla, Y., Ramos Yapo, A. T., Mayta Lampa, S. A., Cruz Cabrera, A. T., Chura Acero, J. F., Chura Yaresi, M. F., & Yana Benito, E. C. (2026). Determination of Effective Thermal Conductivity of Stipa ichu: Numerical Shape Factor Calibration in a Reduced-Scale Hot Box. LACCEI, 1(14). https://doi.org/10.18687/LACCEI2026.1.1.1705