Analysis of dynamic behavior due to wind loads in a 14-level structure with dual system, Trujillo

Authors

  • Luigy Amid Cabrera Acevedo Universidad César Vallejo - (PE), Peru
  • Walter Anthony Salinas Ruiz Universidad César Vallejo - (PE), Peru
  • Eduardo Manuel Noriega Vidal Universidad César Vallejo - (PE), Peru
  • Juan Carlos Martell Ortiz Universidad César Vallejo - (PE), Peru
  • Alan Yordan Valdivieso Velarde Universidad César Vallejo - (PE), Peru
  • Eduar Jose Rodriguez Beltran Universidad César Vallejo - (PE), Peru

DOI:

https://doi.org/10.18687/LACCEI2024.1.1.322

Keywords:

Wind pressure, windward, leeward, wind

Abstract

he general objective of the research work was to carry out an analysis of the dynamic behavior due to wind loads in a 14-story structure with a dual system. The research considered a non-experimental design; in addition, it will be transversal in nature, since it will be carried out in a given circumstance. Also, in a descriptive way, since information will be collected, in order to analyze our variables. To achieve our general and specific objectives, we follow the guidelines and wind parameters of the current ASCE 7-22 (American) standard, where the intensity of the wind speed in a specific direction, the pressures and permissible displacements in the design of a building. For this purpose, calculations were made on a 15-story building, with a height of 37.9 m, 9.8 m in the direction perpendicular to the wind, 23.9 m in the direction parallel to the wind. The study of the building will be carried out in the city of Trujillo which will be through the RFEM 5 and RWIND and ETABS software for the modeling and simulation of the structure due to wind loads, also for the calculation of speeds it was achieved with the help of spreadsheets in Excel, applying the ASCE 7-22 criteria. The results obtained show important variations in speeds and pressures to which the Solano II building is exposed, exerted by the wind on the building since the higher the floor height, the greater the increase in the pressure exerted on the structure with respect to the speed. of the wind, it is also concluded that it is important that each method applied in the present investigation corresponds to a climatological reality of the country where they are located.

Downloads

Published

2024-07-27

License

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

LACCEI retains copyright of all published articles under the terms of its copyright transfer agreement. As the copyright holder, LACCEI distributes the articles to the public under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License (CC BY-NC-SA 4.0).

How to Cite

Cabrera Acevedo, L. A., Salinas Ruiz, W. A., Noriega Vidal, E. M., Martell Ortiz, J. C., Valdivieso Velarde, A. Y., & Rodriguez Beltran, E. J. (2024). Analysis of dynamic behavior due to wind loads in a 14-level structure with dual system, Trujillo. LACCEI, 1(10). https://doi.org/10.18687/LACCEI2024.1.1.322

Most read articles by the same author(s)