Early detection system for LPG leaks in tanker vehicles using the MQ-5 sensor

Autores/as

  • Eduardo Alfonso Anci García Universidad Tecnológica del Perú UTP - (PE), Perú
  • Diana Karolina Rosas Huertas Universidad Tecnológica del Perú UTP - (PE), Perú
  • Jorge Polanco Argüelles Universidad Tecnológica del Perú UTP - (PE), Perú
  • Giancarlo Franko Sanchez Chavez Universidad Tecnológica del Perú UTP - (PE), Perú

DOI:

https://doi.org/10.18687/LACCEI2026.1.1.1834

Palabras clave:

LPG leak detection, MQ-5 sensor, Arduino Uno, vehicular safety, response time

Resumen

Liquefied petroleum gas transportation in tank trucks represents a critical risk due to leaks that can cause explosions, such as the Villa El Salvador accident (2020) with 34 fatalities. This study developed and experimentally validated an early detection system based on the MQ-5 sensor and Arduino Uno microcontroller. A total of 120 trials were conducted at four distances (1, 5, 10, 15 cm) with 30 repetitions each, establishing a threshold of 400 ADC units. Results showed response times between 0.98 and 3.37 seconds, lower than the 10-second standard. The system achieved 92.50% accuracy with perfect 100% precision (zero false alarms) and 91% sensitivity. Analysis of variance confirmed that distance significantly affects response time (F=557.03, p<0.000001), establishing a predictive model (R2=0.9985): Time = 0.171×Distance + 0.629. Energy consumption (<250 mW) and low cost (~$40 USD) confirm its viability for vehicular applications, providing the first scientific quantification of the distance-time relationship for MQ-5 sensors.

Descargas

Publicado

2026-07-27

Número

Sección

Articles

Licencia

Licencia Creative Commons

Esta obra está bajo una Licencia Creative Commons Atribución-NoComercial-CompartirIgual 4.0 Internacional.

LACCEI conserva el copyright de todos los artículos publicados bajo los términos de su acuerdo de transferencia de copyright. Como titular del copyright, LACCEI distribuye los artículos al público bajo la Licencia Internacional Creative Commons Atribución-NoComercial-CompartirIgual 4.0 (CC BY-NC-SA 4.0).

Cómo citar

Anci García, E. A., Rosas Huertas, D. K., Polanco Argüelles, J., & Sanchez Chavez, G. F. (2026). Early detection system for LPG leaks in tanker vehicles using the MQ-5 sensor. LACCEI, 1(14). https://doi.org/10.18687/LACCEI2026.1.1.1834

Artículos más leídos del mismo autor/a