GUI for the Analysis of Direct Flashover Shielding Failure in Overhead Power Lines

Authors

  • José Luis Julca García Universidad Tecnológica del Perú UTP - (PE), Peru
  • Yoel Yonel Rojas Marcelo Universidad Tecnológica del Perú UTP - (PE), Peru
  • Joel Villavicencio Gastelu Universidad Tecnológica del Perú UTP - (PE), Peru
  • Angel Eduardo Obispo Vasquez Universidad Tecnológica del Perú UTP - (PE), Peru

DOI:

https://doi.org/10.18687/LACCEI2026.1.1.1606

Keywords:

Overhead transmission lines, shielding failure, direct flashover, lightning

Abstract

The analysis of the performance of overhead power lines against the direct impact of lightning on phase conductors is a topic of interest in the field of transmission lines. The shielding failure flashover rate (SFFOR) measures this performance. The SFFOR is calculated after solving a set of complex equations, which may result in unintentional errors and require excessive computation time if the calculations are performed manually. In this study, a graphical user interface (GUI) was developed to compute the SFFOR. In contrast to existing similar tools, the developed GUI allows for the modelling of the probability density of the lightning current magnitude from historical data. In addition, the GUI can determine the optimal shielding angle. The equations for the SFFOR computation were obtained from the standard IEEE-1410 and -1253 and brochure 063 of CIGRE. The application of the proposed methodology to a 33 kV overhead power line located at 2700 m.s.n.m. indicated an SFFOR of 0.32 and 0.00 flashovers/100 km-year. The first result was obtained using the parameters of the log-normal function provided in the brochure 063. The second result considered the parameters of the distribution function determined by the proposed method. This shows the sensitivity of the results to the lightning current modelling. Both values were obtained in less than a second after entering the data into the GUI. Therefore, the developed GUI facilitates the analysis of the performance of power transmission shielding, allowing the evaluation of possible shielding improvements in a short time.

Downloads

Published

2026-07-27

License

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

LACCEI retains copyright of all published articles under the terms of its copyright transfer agreement. As the copyright holder, LACCEI distributes the articles to the public under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License (CC BY-NC-SA 4.0).

How to Cite

Julca García, J. L., Rojas Marcelo, Y. Y., Villavicencio Gastelu, J., & Obispo Vasquez, A. E. (2026). GUI for the Analysis of Direct Flashover Shielding Failure in Overhead Power Lines. LACCEI, 1(14). https://doi.org/10.18687/LACCEI2026.1.1.1606

Most read articles by the same author(s)